40-7705ii-UM
Page 109
Rev 1 June 11, 2018
# 2
Line Card
SIC used in Optex Morse Genesys 824 Alpha
Signal format: 1RRLssssssACCTEEsNNNs<0x14>
Line card 2 and SIC Not Supported by MultiNet system
Line Card # 3
Contact ID received from
IntelliTap
. Events are translated.
Signal format:
1RRLssssssACCTEEsNNNs<0x14>
See “Line card #1”, “Signal format” in “Radionics 6500
compatible output” for Key to codes used in signal format for Line Card #3
above.
The received Contact ID formatted message is translated to a Radionics compatible format as described below.
Receiver number is set as programmed in Business Unit of MultiNet receiver. Line card is set to 3.
Event plus Zone, Status and Fault Codes, AES Subscribers with IntelliTap.
Event Codes with numbers E1XX and E2XX will be reported as: see exception
♣
A NNN
where NNN is the Point ID or Contact ID number
♣ Event Codes with numbers E12X will be reported as:
D
( D followed by 4 spaces.)
This is an exception to E1XX above
♣
Event Codes with numbers P1XX and P2XX will be reported as:
SA NNN
where NNN is the Point ID or Contact ID number
Contact ID Event Codes with numbers R121 and contact 000 will be reported as:
A NNN
where NNN is the Point ID or Contact ID number
Event Code E121 C000 will be reported as:
D 000
Event Codes E3XX, and R3XX with non-zero zone data will be reported as:
T NNN
where NNN is the Point ID or Contact ID number
Event Codes with numbers P3XX with non-zero zone data will be reported as:
ST NNN
where NNN is the Point ID or Contact ID number
Event Codes E3XX and R3XX with Point ID or Contact ID value of 000 are reported as:
Y 3XX
where 3XX is a copy of the event code
Event Codes P3XX with Point ID or Contact ID value of 000 will be reported as:
SY 3XX
where 3XX is a copy of the event code
Event Codes with numbers E4XX will be reported as:
O NNN
where NNN is the Point ID or Contact ID number