40-7705ii-UM
Page 70
Rev 1 June 11, 2018
Explanation of the Message Group Functions:
Function
Explanation
SEND TEXT MESSAGE
• Press <ALT>+<A>
or <ALT>+<M>, then <S>
• Select Target Unit
• Select Route
• Type text message
• Press <ALT>+<S> to send
• Sends text messages to a remote subscriber
unit. To receive the data, the remote unit must
have a 7041 Hand Held Programmer attached or
be equipped with a terminal. The most common
use for this function is to test the
communications link by sending data packets.
REQUEST STATUS
• Press <ALT>+<R>
or <ALT>+<M>, then <2>
• Select Target Unit
• Press <ENTER> for route
• Queries a remote unit for its current status,
requiring a "check-in" report back to the central
station. The resulting return message provides
the current status of the remote unit
and
sends a
status (check-in) message to the alarm
automation port. (See the manual section on
messages types and interpretations).
GET SUBSCRIBER
ROUTE TABLE
• Press <ALT>+<G>
or <ALT>+<M>, then <4>
• Select Target Unit
• Select Route
• Queries a remote unit for its current routing
table. It prints the routing table for this
subscriber and displays the routing table from
top (best) to bottom. For each unit on the list,
the following items are displayed:
• ID #
• LINK LAYER # • NETCON
• SIGNAL QUALITY between this unit and
queried unit, listed as Good, Fair or Poor
GET ALL
SUBSCRIBER DATA
• Press <ALT>+<M>, then <5>
or Press <ALT>+<L>
• Select Target Unit
• Select Route
• Queries a remote unit for ALL of it s currently
programmed parameters. The function
automatically performs all the Get functions,
retrieving Timing, Zones, Model #/Rev and
Mode data for the unit you specify. (See
specifics below).
(GET) SUBSCRIBER
TIMING DATA
• Press <ALT>+<M>, then <6>
or Press <ALT>+<I>
• Select Target Unit
• Select Route
• Queries a remote unit for its current timing
parameters. The received data updates the
timing parameters database. Timing parameters
are part of the Programming Function Group
described in the following pages.
(GET) SUBSCRIBER
ZONES DATA
• Press <ALT>+<M>, then <7>
or Press <ALT>+<Z>
• Select Target Unit
• Select Route
• Queries a remote unit for its current zone
configurations. The received data updates the
Zone Configuration database. The Zone
Configuration is part of the Programming
Function Group described in the following
pages.