Radionics 6500 compatible output format:
This mode will provide the output of 3 line cards; line card 1 is for AES subscriber and
receiver signals, line card 3 is for Contact ID signals from
IntelliTap
, and line card 4 is for
4+2 signals from
IntelliTap
.
Contact ID signals are translated into an AES’ Radionics message as outlined under line
card # 3 and 4 elsewhere in this appendix. Due to this translation it is preferred that the
Ademco emulation be used when
IntelliTap
or other contact ID message producing
interfaces are used.
Line Card # 1
AES signals from subscribers and receivers.
Signal format
:
1RRLssssssACCTEEsNNNs<0x14>
Key to codes used in signal format above:
1
= 1 is for automation signal. (a 3 indicates text data)
RR
= Receiver number, user programmable. Between 01 and FF.
L
= Line card number, Line card is selected by firmware or software. 1 - 4
ACCT
= Four digit subscriber ID or 4 blank spaces for AES receiver
EE
= Event code (See event codes below)
NNN
= Zone, status or fault code *
s
= <Blank space>
<0x14>
= Termination character
* Note: The value of NNN or (N2N1N0) in Radionics 6500 format, (or N2 N1 N0 as
used for this example) is computed as follows: Value = N2 X 16 + (N1 X 10 +
N0). The numbers in positions N1 and N0 represent the two digit decimal
equivalent of a single digit hexadecimal number. It will never be greater than
decimal 15. The number in position N2 represent the decimal equivalent of a
Hexadecimal number where 1 = decimal 16 and 2 = decimal 32.