2.1.3. Transformer Options
An external isolation transformer can be connected to the motor supply AC input. This is done to reduce the
operating voltage of the motor and may also reduce electrical noise.
Table 2-5:
Nominal Motor Operating Voltages / Required AC Voltages
AC Voltage
DC Voltage
28
40
56
80
115
160
230
320
Table 2-6:
Transformer Options
Transformer
Description
TV0.3-28-56-ST
Generate 28 or 56 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces a 40 or 80 VDC power bus.
TM3
Power up to 4 drives, providing 300 watts of power
TM5
Power up to 4 drives providing 500 watts of power
TV0.3-28
Generate 28 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces a 40 VDC power bus.
TV0.3-56
Generate 56 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces an 80 VDC power bus.
TV1.5, TV2.5, or TV5
1.5 kVA, 2.5 kVA, or 5 kVA isolation transformer; 115/230 VAC input; 28, 43, 56,
70, 115 VAC output
Figure 2-3:
Transformer Examples
Soloist CP
Installation and Configuration
Summary of Contents for Soloist CP 10
Page 1: ...Revision 4 09 00 Soloist CP Hardware Manual...
Page 14: ...Soloist CP Quick Installation Guide 14 www aerotech com This page intentionally left blank...
Page 24: ...Soloist CP Introduction 24 Chapter 1 www aerotech com This page intentionally left blank...
Page 90: ...90 Chapter 3 www aerotech com Figure 3 7 Digital Inputs Soloist CP IO Expansion Board...
Page 100: ...100 Chapter 4 www aerotech com Soloist CP Accessories This page intentionally left blank...
Page 108: ...Soloist CP Revision History 108 Appendix B www aerotech com This page intentionally left blank...