![Aerotech Soloist CP 10 Hardware Manual Download Page 101](http://html1.mh-extra.com/html/aerotech/soloist-cp-10/soloist-cp-10_hardware-manual_2863050101.webp)
Maintenance
Soloist CP
Chapter 5: Maintenance
D A N G E R : Always disconnect the Mains power connection before opening the Soloist CP
chassis.
D A N G E R : Before performing any tests, be aware of lethal voltages inside the controller and
at the input and output power connections. A qualified service technician or electrician should
perform these tests.
Table 5-1:
LED Description
LED
Description
ENB/FLT
Turns green to indicate that the axis is enabled. Turns red to indicate a fault condition. The
ENB/FLT LED will flash between RED and GREEN if the drive is enabled and in a fault
condition.
MARKER
Turns green to indicate that the marker input is high.
PWR*
Turns green when power is applied.
POS
Turns green to indicate that the axis is in position.
* If the power light flashes continuously and the unit does not operate, there is too much current draw from the 5V power supply or
the control supply voltage level is low.
www.aerotech.com
Chapter 5
101
Summary of Contents for Soloist CP 10
Page 1: ...Revision 4 09 00 Soloist CP Hardware Manual...
Page 14: ...Soloist CP Quick Installation Guide 14 www aerotech com This page intentionally left blank...
Page 24: ...Soloist CP Introduction 24 Chapter 1 www aerotech com This page intentionally left blank...
Page 90: ...90 Chapter 3 www aerotech com Figure 3 7 Digital Inputs Soloist CP IO Expansion Board...
Page 100: ...100 Chapter 4 www aerotech com Soloist CP Accessories This page intentionally left blank...
Page 108: ...Soloist CP Revision History 108 Appendix B www aerotech com This page intentionally left blank...