Installation and Configuration
Npaq MR Hardware Manual
2.2.1. AC Power Connections
AC input power to the Npaq MR drive chassis is applied to the AC power receptacle that is located on the
rear panel. The power cord connected to this receptacle also provides the protective earth ground connection
and may serve as a Mains disconnect. The main power switch located on the front panel of the Npaq MR
drive chassis also functions as a 10 A breaker (supplementary protection only) for the incoming AC power.
The Npaq MR drive chassis is factory configured for one of four specified input voltages. The factory
configured AC input voltages, along with the current requirements for the Npaq MR drive chassis, are listed
in
.
Table 2-1:
Main AC Power Input Voltages and Current Requirements
AC Input Voltage
Input Amps (maximum continuous)
100 VAC 50/60 Hz
10 A
115 VAC 50/60 Hz
10 A
200 VAC 50/60 Hz
6 A
230 VAC 50/60 Hz
5 A
The AC power cord/wiring specifications are listed in
. Environmental conditions may necessitate
the need to meet additional AC wiring requirements or specifications. AC wiring should not be bundled with
signal wiring to minimize EMI coupling and interference.
Table 2-2:
AC Power Wiring Specifications
Specification
Value
Cord/Wire Rating
300 V
Minimum Current Capacity
10 A
Temperature Rating (Insulation)
(1)
80°C
1. The insulation rating for the AC power wiring must be appropriately rated for the operating environment.
Refer to
for label locations.