![Aerotech Automation1 iXR3 Hardware Manual Download Page 58](http://html1.mh-extra.com/html/aerotech/automation1-ixr3/automation1-ixr3_hardware-manual_2863027058.webp)
2.4.1. PSO Isolated Outputs
This output signal is a fully-isolated 5-24V compatible output capable of sourcing or sinking current.
Refer to
and
.
This output is normally open and only conducts current when a PSO fire event occurs.
The PSO Isolated Outputs are overload protected and will turn off if the maximum output current is
exceeded.
Table 2-21:
PSO Isolated Output Specification
Specification
Value
Outputs (±)
5-24 V, 250 mA
Table 2-22:
Isolated Output Pins on the PSO Connector
Pin # Description
In/Out/Bi
15
PSO Output 3 - (Isolated) [A3200: PSO Output 2 -]
Output
16
PSO Output 3 + (Isolated) [A3200: PSO Output 2 +]
Output
17
PSO Output 2 - (Isolated) [A3200: PSO Output 1 -]
Output
18
PSO Output 2 + (Isolated) [A3200: PSO Output 1 +]
Output
19
PSO Output 1 - (Isolated) [A3200: PSO Output 0 -]
Output
20
PSO Output 1 + (Isolated) [A3200: PSO Output 0 +]
Output
Figure 2-27:
PSO Output Sources Current
Figure 2-28:
PSO Output Sinks Current
2.4.1. PSO Isolated Outputs
iXR3/XR3 Hardware Manual
58
www.aerotech.com
Summary of Contents for Automation1 iXR3
Page 1: ...Revision 2 08 Automation1 iXR3 and XR3 Drive Racks HARDWARE MANUAL...
Page 97: ...Figure 3 3 Slot Details iXR3 XR3 Hardware Manual 3 3 Amplifier Replacement www aerotech com 97...
Page 111: ...W Warranty and Field Service 99 iXR3 XR3 Hardware Manual Index www aerotech com 111...
Page 112: ...Index iXR3 XR3 Hardware Manual This page intentionally left blank 112 www aerotech com...