![Aerotech Automation1 iXR3 Hardware Manual Download Page 32](http://html1.mh-extra.com/html/aerotech/automation1-ixr3/automation1-ixr3_hardware-manual_2863027032.webp)
Figure 2-2:
XR3 Connection Overview
All low voltage connections must be made using cables and wires sized for the maximum currents
that will be carried. Insulation on these cables and wires must be rated at 300 V if this wiring can
come into contact with wiring operating above 100 V (AC and motor wiring). Low voltage wiring
should not be bundled with AC and motor wiring to minimize signal disturbances due to EMI
interference and coupling.
IMPORTANT
: The machine integrator, OEM or end user is responsible for meeting the
final protective grounding requirements of the system.
DANGER
: Disconnect power before you do maintenance to the equipment. Wait at
least ten (10) minutes after removing the power supply before doing maintenance or an
inspection. Otherwise, there is the danger of electric shock.
WARNING
: Before powering on the iXR3/XR3, verify that all drive modules and cables
to the iXR3/XR3 have been properly installed. Refer to the remaining chapters of this
manual for installation and configuration procedures.
Confirm that the AC power is the correct voltage before turning on power to the
iXR3/XR3.
2.1. Electrical Installation
iXR3/XR3 Hardware Manual
32
www.aerotech.com
Summary of Contents for Automation1 iXR3
Page 1: ...Revision 2 08 Automation1 iXR3 and XR3 Drive Racks HARDWARE MANUAL...
Page 97: ...Figure 3 3 Slot Details iXR3 XR3 Hardware Manual 3 3 Amplifier Replacement www aerotech com 97...
Page 111: ...W Warranty and Field Service 99 iXR3 XR3 Hardware Manual Index www aerotech com 111...
Page 112: ...Index iXR3 XR3 Hardware Manual This page intentionally left blank 112 www aerotech com...