2.2.3. Stepper Motor Connections
The configuration shown in
is an example of a typical stepper motor connection. Refer to
for information on motor phasing.
In this case, the effective motor voltage is half of the applied bus voltage. For example, an 80 V motor
bus supply is needed to get 40 V across the motor.
Figure 2-10:
Stepper Motor Configuration
2.2.3.1. Stepper Motor Phasing
A stepper motor can be run with or without an encoder.
Without an Encoder:
You do not need to phase the motor.
With an Encoder:
Because the end of travel (EOT) limit inputs are relative to motor rotation, it is
important to phase the motor.
Run a positive motion command. The motor is phased correctly if there is a positive scaling factor
(determined by the ServoLoopSetup parameter) and the motor moves in a clockwise direction when
you view the motor from the front mounting flange (
). If the motor moves in a
counterclockwise direction, reverse the motor leads and re-run the command. After the motor has
been phased, if you want to change the direction of positive motion, use the ReverseMotionDirection
parameter.
Figure 2-11:
Positive Motor Direction
For Aerotech-supplied systems, the motor, encoder and Hall sensors are correctly configured and
connection adjustments are not necessary.
iXR3/XR3 Hardware Manual
2.2.3. Stepper Motor Connections
www.aerotech.com
41
Summary of Contents for Automation1 iXR3
Page 1: ...Revision 2 08 Automation1 iXR3 and XR3 Drive Racks HARDWARE MANUAL...
Page 97: ...Figure 3 3 Slot Details iXR3 XR3 Hardware Manual 3 3 Amplifier Replacement www aerotech com 97...
Page 111: ...W Warranty and Field Service 99 iXR3 XR3 Hardware Manual Index www aerotech com 111...
Page 112: ...Index iXR3 XR3 Hardware Manual This page intentionally left blank 112 www aerotech com...