![Aerotech Automation1 iXR3 Hardware Manual Download Page 23](http://html1.mh-extra.com/html/aerotech/automation1-ixr3/automation1-ixr3_hardware-manual_2863027023.webp)
Table 1-4:
PWM Amplifier Electrical Specifications
XSP3-10
XSP3-20
XSP3-30
Option Code
-P1
-P2
-P3
Peak Motor Output Current (2 sec)
(1)
10 A (pk)
20 A (pk)
30 A (pk)
Continuous Current
5 A
10 A
10 A
Peak Bus Voltage
320 VDC
Maximum Power Amplifier
Bandwidth
(3)
2 kHz
PWM Switching Frequency
20 kHz
Minimum Load Inductance
0.1 mH @ 160 VDC (1.0 mH @ 320 VDC)
Heat Sink Temperature (maximum
allowable)
75 °C (All Amplifiers)
1. AC voltage, Bus supply / load may result in significantly lower maximum peak currents.
2. Peak and continuous output current is load dependent. The controller will limit its output current based on velocity and
motor resistance.
3. Selectable through parameters.
Table 1-5:
Linear Amplifier Electrical Specifications
XSL3-10-40
(5)(6)(7)(8)
Option Code
-L1
Continuous Output Current,
±40V bus (A
pk
)
(2)(3)(4)
1.5 A | 2.0 A | 1.0 A
Peak Current (A
pk
)
10 A
(1)
Maximum Continuous Total
Power Dissipation
(3)(4)
120 W | 160 W | 120 W
Peak Amplifier Power
Dissipation per phase
400 W
Effective Heatsink Thermal
Resistance
(3)
0.42°C/W | 0.31°C/W | 0.42°C/W
Maximum Transistor Temperature
75°C
Time to reach maximum
temperature at maximum
continuous power
20 minutes
(1) This specification depends on the motor supply voltage, the motor speed, and motor resistance. Contact an Aerotech
sales engineer for more information.
(2) This specification assumes a motor winding resistance of 0 Ω.
(3) The first number is for a stationary AC or DC motor. The second number is for an AC motor that is in motion. The third
number is for a stepper motor.
(4) The specification will de-rate when the ambient temperature exceeds 25°C.
(5) The XSL3 amplifier has circuitry that will limit peak power to protect itself from damage. In the Status Utility, the Power
Limiting bit under Drive Status monitors the condition of the circuitry. If the circuit is open, the Power Limiting bit will show
as "ON".
(6) All linear amplifier (XSL3-10-40) specifications assume that the fan tray is installed, the fans are set to full-speed mode,
and the ambient temperature is 25°C.
(7) The transistor temperature can be up to 25°C higher than the heat sink temperature that is shown in the Status Utility.
Set the AverageCurrentFault parameter to ensure that the heat sink power dissipation is not exceeded.
(8) Aerotech recommends that you do not use high-current stepper motors with the XSL3-10-40 linear amplifier because of
high-power dissipation. Contact Aerotech for additional information.
iXR3/XR3 Hardware Manual
1.1. Electrical Specifications
www.aerotech.com
23
Summary of Contents for Automation1 iXR3
Page 1: ...Revision 2 08 Automation1 iXR3 and XR3 Drive Racks HARDWARE MANUAL...
Page 97: ...Figure 3 3 Slot Details iXR3 XR3 Hardware Manual 3 3 Amplifier Replacement www aerotech com 97...
Page 111: ...W Warranty and Field Service 99 iXR3 XR3 Hardware Manual Index www aerotech com 111...
Page 112: ...Index iXR3 XR3 Hardware Manual This page intentionally left blank 112 www aerotech com...