Table 1-3:
Electrical Specifications
Description
Option
Specification
Bus Voltage Options
[Factory Configured]
-VB1
±10 VDC (200 W Power Supply), bipolar
-VB2
±20 VDC (200 W Power Supply), bipolar
-VB3
±30 VDC (200 W Power Supply), bipolar
-VB4
±40 VDC (300 W Power Supply), bipolar
-VB5
±80 VDC (300 W Power Supply), bipolar
-VB7
+160 VDC, unipolar
-VB8
+320 VDC, unipolar
Input Current
-VL1
115 VAC, 10 A Maximum
-VL2
230 VAC, 5 A Maximum
-VL3
100 VAC, 10 A Maximum
-VL4
200 VAC, 5 A Maximum
AC Power Input
AC input (Switch Selectable): AC Hi, AC Lo, Earth Ground ( ),
l
100 VAC (90-112 VAC, 50/60 Hz)
l
115 VAC (103-127 VAC, 50/60 Hz)
l
200 VAC (180-224 VAC, 50/60 Hz)
l
230 VAC (207-254 VAC, 50/60 Hz)
Note: If the iXR3/XR3 contains an offline Bus power supply, the AC Input will
be limited to one AC input range.
Inrush Current
32 A Peak
Auxiliary Power Outputs
+5 V provided on all axis feedback connectors for encoder,
Hall, and limit power.
+5 V provided on I/O connectors
Protection
The AC power cord serves as the mains breaker and provides
10 A, Supplemental Protection only.
Internal Bus supply fusing.
Amplifier Output short circuit protection.
Peak and RMS over current limit.
Over Temperature shutdown.
Bus supply inrush current limit during initial power-on.
Indicator (Power)
Opto and transformer isolation between control and power
stages.
Indicator (Enabled)
Power switch contains a power-on indicator.
Protection
Individual Amplifier LED’s indicates drive enabled state.
1.1. Electrical Specifications
iXR3/XR3 Hardware Manual
22
www.aerotech.com
Summary of Contents for Automation1 iXR3
Page 1: ...Revision 2 08 Automation1 iXR3 and XR3 Drive Racks HARDWARE MANUAL...
Page 97: ...Figure 3 3 Slot Details iXR3 XR3 Hardware Manual 3 3 Amplifier Replacement www aerotech com 97...
Page 111: ...W Warranty and Field Service 99 iXR3 XR3 Hardware Manual Index www aerotech com 111...
Page 112: ...Index iXR3 XR3 Hardware Manual This page intentionally left blank 112 www aerotech com...