Deployment Guide
101
R
EPLACING
P
OWER
S
UPPLIES
R
EPLACING
P
OWER
S
UPPLIES
The high capacity HiveManager has a pair of redundant, hot-swappable power supplies. If one of the power supplies
fails, the other will continue to power the device. When a a power supply fails, a continuous beeping alarm sounds
and the power LED glows amber. To replace the failed power supply, do the following:
1. Disconnect the failed power supply from the power source.
2. Lower the handle to a horizontal position.
3. With your index finger, press the red release lever to the left.
4. While holding the release lever to the left, grip the handle between your thumb and second finger, and pull the
power supply straight out. See
Figure 7
.
Figure 7
Removing a power supply
5. Insert a working power supply into the vacant bay and push it straight in until it is fully seated.
The red release automatically slides back to the right to secure the power supply in place.
6. Connect the power supply to the power source.