![Aeris ATMOS ai Operating Manual Download Page 84](http://html1.mh-extra.com/html/aeris/atmos-ai/atmos-ai_operating-manual_2861740084.webp)
84
RESET FEATURE
This dive computer is configured with a RESET feature that allows data to be cleared, including
Nitrogen and Oxygen calculations, FO2 set point, Log Mode entries, and Download data.
WARNING: Reset after a dive and subsequent use for a repetitive dive con-
ducted by the same diver could result in serious injury to or death.
RESET PROCEDURE
While in SURFACE MODE (new activation period or greater than a 10 minute post dive sur-
face interval), press the Advance (Front) button one (1) time to access PLAN MODE.
While 30 feet (or 9 meters) is displayed in the PLAN MODE, press and hold Both buttons until
SET 2 appears, then release the buttons.
Press and release the Advance (Front) button to display the first 2 digits of the KEY CODE,
flashing as 00.
Press and release the Select (Bottom) button to increase the digits to
01
.
Press and release the Advance (Front) button again to display the second 2 digits of the KEY
CODE, flashing as 00.
Press and release the Select (Bottom) button to increase the digits to
01
.
Press and release the Advance (Front) button to complete the RESET operation and turn the
unit OFF.