If you descend below the required decompression ceiling before 5 minutes have elapsed, the
ATMOS ai will continue to function in Decompression Dive Mode. In this case, no off-gassing
credit will be given, and for each minute above the ceiling 1
1
/
2
minutes of
Penalty Time
will be
added to Required Stop Time.
The added Penalty (decompression) Time will have to be 'worked off' first, before obtaining off-
gassing credit.
Once the Penalty Time is worked-off, and off-gassing credit begins, required decompression Stop
Depths and Time will decrease toward zero, then the Nitrogen Bar Graph will recede into the yel-
low Caution Zone and the ATMOS ai will revert to the No Decompression Dive Mode.
NOTE: Upon entry into Delayed Violation Modes, the Audible Alarm will
sound for 10 seconds, even if it is user Set OFF. It cannot be turned off (ac-
knowledged) by pressing the Advance (Front) button.
Delayed Violation Mode #1
(Fig. 54)
If you remain above the Required Ceiling Stop Depth for
'more than 5 minutes',
the Nitrogen Bar Graph and Total Ascent
Time display will flash until you descend below the Required Stop
Depth.
This is a continuation of a Conditional Violation.
Fig. 54 - Delayed Violation #1
Full BG Flashing