35
TO SET - TURN PRESSURE ALARM
(while in the Surface Mode)
Factory set for 00 PSI/BAR (disabled), the Turn Pressure Alarm
can be set to values between 1000 and 3000 PSI (69 to 205 BAR)
in increments of 250 PSI (17 BAR).
Press Both buttons simultaneously, release when SET: 2 ap-
pears.
Press and release the Advance (Front) button, the Units screen
appears with the set point flashing.
Press the Advance (Front) button
9 more times.
The graphic
trn
and Alarm (speaker) icon appear with the
Turn
Pressure Alarm
value flashing (Fig. 34).
Press and hold the Select (Bottom) button to scroll through the
Alarm values.
Press the Advance (Front) button to accept the setting and ad-
vance to Set End Pressure Alarm, or press and hold Both buttons
for 2 seconds to revert to Surface Mode.
Fig. 32 - Set Turn Pressure Alarm