![ADB Safegate IDM 8000 User Manual Download Page 50](http://html1.mh-extra.com/html/adb-safegate/idm-8000/idm-8000_user-manual_2847402050.webp)
4.6.1 Output Current Step Setting
These settings define the output current levels of the CCR. If less than 7 steps are used it is recommended that the step no 7
is always the maximum current step of the CCR. This is because step no 7 is used for tapping info during commissioning (in
local mode).
Header / function
Data 1
Data 2
Fact set Allowed range
Output current set
Step 1 set level
Step 1
2.20A
1.00-6.60A in 0.05A steps
Step 2 set level
Step 2
2.50A
1.00-6.60A in 0.05A steps
Step 3 set level
Step 3
2.80A
1.00-6.60A in 0.05A steps
Step 4 set level
Step 4
3.40A
1.00-6.60A in 0.05A steps
Step 5 set level
Step 5
4.10A
1.00-6.60A in 0.05A steps
Step 6 set level
Step 6
5.20A
1.00-6.60A in 0.05A steps
Step 7 set level
Step 7
6.60A
1.00-6.60A in 0.05A steps
I2
Conf CF ?
Accept current step values and recalculate current fault alarm levels.
Setting sequence
1. Go to output current settings by selecting Set/Set/Out.
1. If necessary adjust step 1 level with , + / - , select Set and then select Next.
1. Repeat step 2 until all 7 steps are set.
1. Select Set for Conf CF? - If you want to update the current fault monitoring values now. If you want to test the current fault monitoring
skip this but remember to confirm it later.
4.6.2 Lamp Fault Setting
These settings define the amount of lamps faults that generates a lamp fault alarm after a predefined delay time. 2 levels A
and B are provided.
Header / function
Data 1
Data 2
Fact set
Allowed range
Lamp fault set
No of lamp faults
Level A
2
1-99 lamps in 1 lamp steps
No of lamp faults
Level B
1
1-99 lamps in 1 lamp steps
Delay time
Delay
10s
1-99s in 1s steps
IDM 8000
User Interface
38
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for IDM 8000
Page 1: ...IDM 8000 CCR User Manual UM_IDM 8000 Rev 1 7 2021 05 06 ...
Page 2: ......
Page 8: ...IDM 8000 TABLE OF CONTENTS viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...IDM 8000 List of Figures x Copyright ADB Safegate All Rights Reserved ...
Page 12: ...IDM 8000 List of Tables xii Copyright ADB Safegate All Rights Reserved ...
Page 18: ...IDM 8000 Safety 6 Copyright ADB Safegate All Rights Reserved ...
Page 20: ...IDM 8000 About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Page 76: ...IDM 8000 Troubleshooting 64 Copyright ADB Safegate All Rights Reserved ...
Page 104: ...IDM 8000 Appendix J Spare part list 92 Copyright ADB Safegate All Rights Reserved ...
Page 106: ...IDM 8000 Appendix K Components of electronics 94 Copyright ADB Safegate All Rights Reserved ...
Page 113: ...UM_IDM 8000 Rev 1 7 2021 05 06 101 Copyright ADB Safegate All Rights Reserved ...
Page 114: ...IDM 8000 Appendix M Output Terminals 102 Copyright ADB Safegate All Rights Reserved ...
Page 118: ......