6. Mount the new cable gland gaskets.
7. Replacement:
a. Pull the secondary wires through the Strain-relief Plate and the cable gland gaskets and
b. Mount the new secondary cable by torquing the new Strain-relief Bolt at.XX in-lbs (XX Nm).
8. Locking:
a. Lock the secondary cables leading to the converter by opening the cable holes prying a thin screwdriver on the cable
release opening and mounting the wires in place and
b. Lock the cables by releasing screwdriver from the opening.
9. Close the light.
Note
Refer to the
Closing a Light Fixture — connecting the Bottom Pan to the Top Cover
section.
5.3.10 Resetting the Fail-open Converter
Parts
•
Fuse resistor spare part kit: 20210209 (20 pcs)
Info
•
Converter with 1 connector have 2 fuse resistors
•
Converter with 2 connectors have 4 fuse resistors
Reset / replace the fuse resistors
1. Disconnect and disassemble the light fixture.
2. Locate the fuse resistors.
Note
Refer to
figures.
Refer to Figure.
Figure 18: Converter, 1-connector
AXON Taxiway Inset Lights, 8-inch and 12-inch
Maintenance