SERIES APZU+ ACROPACK
USER’S MANUAL
Acromag, Inc. Tel: 248-295-0310 -
69
-
www.acromag.com
8.0 SPECIFICATIONS
8.1 Physical
Height:
12.5
mm
(0.4921
in)
Height defines Carrier to Module Maximum component height
Board Thickness
1.0 mm (0.03937 in)
AcroPack L x W: 70 mm x 30.00 mm
(2.76 in x 1.18 in)
Unit Weight with heat sink (does not include shipping material):
AcroPack 1.24 ounces (35.18 g)
8.2 Power Requirements
8.3 Environmental Considerations
8.3.1 Operating Temperature
Model Number
Description
Temp Range
APZU-301
1
28 TTL I/O
-40
o
C
to 75
o
C
1,2
APZU-303
1
20 TTL & 3 RS485/422
-40
o
C
to 75
o
C
1,2
APZU-304
1
14 LVDS I/O
-40
o
C
to 75
o
C
1,2
Note 1
:
A
minimum airflow of 400LFM is recommended. .
Note 2:
Do not run the module without the heatsink. Running the
module without a heatsink will reduce the life expectancy of the Zynq
IC.
Summarized below are the expected current draws for each of the specified
power supply voltages.
Power Supply Voltage Current Draw
3.3 VDC +/- 5%
1
57 mA Typical, 100 mA maximum
1.5 VDC +/- 5%
1
Not Used
5.0 VDC +/- 5%
1
183 mA Typical, 230 mA maximum
+12 VDC +/- 5%
1
165 mA Typical, 200 mA maximum
-12 VDC +/- 5%
1
Not Used
Note 1
:
Typical current draw for all models with Acromag Example design
Summarized below are the operating temperature range, airflow
and other environmental requirements and applicable standards for
the AcroPack module.