90
˙
Contact input capacity is 24 Vdc 8mA or less.
˙
Circuit leakage current at signal OFF must be 100µA or less.
Wiring example (Open-collector input)
Note: When the multifuntion contact input is selected as JOG command, the Jog frequency.
2.7.16
MULTIFUNCTION PHOTO- COUPLER OUTPUT FUNCTION SELECTION
Item Name
Constant to be set
Factory Preset
Multifunction Contact Output Fubction
34 , 35
See page 64
Set Value Function
Page
1
External fault (NO contact input)
101
2
External fault (NC contact input)
101
3
Multi-step speed reference 1
72
4
Multi-step speed reference 2
72
5 JOG
command
73
6 Accel/decel
time
select
71
7 External
baseblock
(NO contact input)
107
8 External
baseblock
(NC contact input)
107
9
Search command from maximum frequency
96
10
Search command from settingfrequency
96
11 Accel/decel
prohibit
command
98