13
switching and may cause devices to be damaged or to malfunction. Select type from Table 1.3.
Table 1.3 Surge Absorbers
Surge Absorber*
Coils of Magnetic Contactor and
Control Relay
Model DCR2-
Specifications
Large-size Magnetic
Contactors
50A 22E
220 VAC
0.5uF 200 ohm
200V
to
230V
Control Relay
MY-2,-3(OMRON)
HH-2, -23(FUJI)
MM-2,-4(OMRON)
10A 25C
250
VAC
0.1uF 100
380 to 460 V Units
50D 100B
1000 VDC
0.5uF 220 ohm
*Made by MARCON Electronics.
(5)Wire and terminal screw sizes
Table 1.4 shows wire sizes and types.
Table 1.4 Wire Size
˙
220V Class 3-phase Input Series
Wire Size
Wire Type
Circuit
Model
JNTAABD-C
B
Inverter
Capacity
(KVA)
Terminal Symbol
Terminal
Screw
AWG
mm²
R500JK---
1.4
R, S, T, B1/P, B2, U, V, W
E
M4
1 4 –10
14 -10
2 to 5.5
2 to 5.5
0001JK---
2.1
R, S, T, B1/P, B2, U, V, W
E
M4
1 4 –10
14 -10
2 to 5.5
2 to 5.5
0002JK---
2.7
R, S, T, B1/P, B2, U, V, W
E
M4
12 -10
14 -10
3.5 to 5.5
2 to 5.5
0003JK---
4.1
R, S, T, B1/P, B2, U, V, W
E
M4
12 -10
14 -10
3.5 to 5.5
2 to 5.5
0005JK---
6.9
R, S, T, B1/P, B2, U, V, W
E
M4
12 -10
14 -10
3.5 to 5.5
2 to 5.5
7R50JK---
10.3
R, S, T, B1/P, B2, U, V, W
E
M5
10 -8
14 -10
5.5 to 8
2 to 5.5
Main Circuit
0010JK---
13.7
R, S, T, B1/P, B2, U, V, W
E
M5
10 -8
14 -10
5.5 to 8
2 to 5.5
Power cable:
600V
vinylsheathed
lead or
equivalent
Control
Circuit
Common to
All Models
1 ~ 14 , A , B , C
M3.5
20 -14
0.5 to 2
Shielded lead
or equivalent