2 System setup
32
Setting up your system
Setup reminders
•
Do not attempt to modify or use the supplied AC power cord if it is
not the exact type required. A product with more than one power
supply will have a separate AC power cord for each supply.
•
The power button on the system does not turn off system AC
power. To remove AC power from the system, you must unplug
each AC power cord from the wall outlet or power supply. The
power cord(s) is considered the disconnect device to the main (AC)
power. The socket outlet that the system plugs into shall be
installed near the equipment and shall be easily accessible.
Pre-setup safety steps
Whenever you remove the chassis panels to access the inside of the
system, follow these steps:
1
Turn off all peripheral devices connected to the system.
2
Turn off the system by pressing the power button.
3
Unplug all AC power cords from the system or from wall outlets.
4
Label and disconnect all cables connected to I/O connectors or
ports on the back of the system.
5
Provide some electrostatic discharge (ESD) protection by wearing
an antistatic wrist strap attached to chassis ground of the system—
any unpainted metal surface—when handling components.
6
Do not operate the system with the chassis panels removed.
After you have completed the six steps above, you can remove the
chassis panels. To do this:
1
Unlock and remove the padlock from the back of the system if a
padlock has been installed.
2
Remove and save all screws from the panels.
3
Remove the panels.
For proper cooling and airflow, always reinstall the chassis panels
before turning on the system. Operating the system without the these
panels in place can damage system parts. To install the chassis panels:
AA G900 ug - EN.book Page 32 Wednesday, September 25, 2002 5:23 PM
Summary of Contents for Altos G900
Page 1: ...Acer Altos G900 User s guide ...
Page 10: ...x ...
Page 16: ...xvi ...
Page 17: ...1 System tour ...
Page 43: ...2 System setup ...
Page 44: ...This chapter describes the system setup procedures both for hardware and software aspects ...
Page 55: ...3 Hardware configuration ...
Page 56: ...This chapter describes detailed procedures for system hardware setup ...
Page 127: ...4 BIOS setup ...
Page 160: ...4 BIOS setup 144 ...
Page 161: ...Appendix A System rack installation ...
Page 162: ...This appendix describes the procedures for configuring the system in a rack mount fashion ...
Page 175: ...159 5 Slide the server into the rack Figure 70 Mounting the server to the rack ...
Page 176: ...Appendix A System rack installation 160 ...
Page 177: ...Appendix B System management ...
Page 210: ...Appendix B System management 194 ...
Page 211: ...Appendix C Equipment log and configuration worksheets ...
Page 217: ...201 ...
Page 218: ...Appendix C Equipment log and configuration worksheets 202 ...
Page 219: ...Appendix D Troubleshooting ...