Installing the BMC module
The optional BMC module allows system administrators to manage the
Altos G540 system remotely over a network.
To install the BMC module:
1
Perform the pre-installation instructions described on page 37.
2
Locate the IPMB_6 slot. If necessary, remove any boards or cables
that prevent access to it.
3
If necessary, open the holding clips of the IPMB_6 slot.
4
Remove the BMC module from its protective packaging, handling
it by the edges.
5
Install the BMC module.
(1) Align the module so that the notch on the IPMB_6 slot fits the
keyed edge of the module, then press the module at both
ends to seat it fully into the slot.
When the module is properly installed, the holding clips will
automatically lock in place.
(2) Secure the module with the one screw.
6
Observe the post-installation instructions described on page 38.