28
www.acclaimlighting.com
TO FIT THE AI FLEX TAPE
1 If necessary, cut the channel to the length required. Ensure that any resulting burrs are
removed.
2 Ensure the tape mounting surface within the channel is completely dry, clean and free of
grease. If cleaning is required, please see page 4 for details.
3 Determine the length of tape required. If necessary, leave a gap at
each end. Mark the positions at each end of the channel where
the tape will be placed.
Note: Ai Flex tape can be cut every 1” (25mm), which
may slightly constrain the precise lengths of tape
that can be achieved. Therefore it may be
beneficial to center the tape within
the channel to achieve an even
distribution.
4 Cut the tape to the nearest marked
cutpoint.
5 If necessary, carefully solder to the
contact pads or use a feed/link
cable (see page 5).
6 Begin peeling the backing from the Ai
Flex tape and carefully stick the Ai Flex tape
into the channel, starting at the marked position.
IMPORTANT: While pressing the Ai Flex tape into position, take care not to put
excessive pressure on the components or connections.
+24
V
W1
W2
W3
W4
TO RECESS A CHANNEL WITHIN A DRYWALL CEILING
1 Make a gap within the drywall ceiling panels (measuring 1¼” / 32mm wide x the length of
the channel). Place the
Flex drywall mount
into the gap so the wings of the mount rest on
the ceiling panels.
Note: If required, fit
Mount end caps
at each end of the mount.