54
Close both tamper contacts of the WAM and wait until it emits a
double tone.
6.6
Factory default setting
To delete all settings in the accessory module and all detectors,
proceed as follows:
In the main programming menu, select item 8 (LED 8 lights up).
Confirm by pressing SET.
All LEDs flash.
Keep ESC/DEL pressed until the accessory module emits a double
tone as confirmation and LED 8 lights up. The programming and all
trained wireless detectors are now deleted.
Note: To exit menu item 8 without making a factory reset, only
press ESC/DEL briefly.
After restoring the factory default settings, exit the programming
mode by pressing ESC/DEL.
The LED for the power supply lights up/flashes and the fault LED
lights up. The accessory module beeps at short intervals.
Close both tamper contacts of the WAM and wait until it emits a
double tone.
7. Technical
data
Power supply:
12 V DC
Power consumption:
70 mA when idle
90 mA with activated relay
240 mA with activated relay and
battery charge
Emergency power supply: 6 V DC, 1.2 Ah
Number of channels:
8
Display:
10 LEDs
Outputs:
4 x transistor relays (NO/NC)
Max. switching power 500 mA,
24 V DC, R = 2
Ω
1 x RJ12 for triggering the sirens
Inputs: 2
Compatibility: Secvest
Terxon
LX
Terxon
MX
Terxon
SX
Wireless smoke detector
Wireless motion sensor
Wireless magnetic contact
Wireless vibration detector
Wireless glass breakage detector
Remote
control
(FU5150/FU5155)