Encrypting the HPE 200AVP Ethernet adapters

 

 

By default the adapters are NOT encrypted, so if your installation does not require encryption, the 
adapters can be installed and used, straight out of the box.  

 

To create a secure, encrypted connection between adapters, follow these steps. 

 

1.  Connect the adapters to the power outlets closest to the area you plan to use them. 

 

NOTE: To insure connectivity between the adapters, all adapters you wish to network together must 
be on the same circuit in your breaker box.

 

 

2.  Press and hold the security button on the

 first adapter 

for about 10 to 15 seconds; release it when the device 

LEDs turn off.  

 

3.  All three LEDs will then come on for 1 second and turn off again signifying the device reboot. After the reboot 

the 

Power

 LED will come back on solid green and the device will have generated a unique encryption key. 

 

4.  Press and hold the security button on the

 second adapter 

for about 10 to 15 seconds; release it when the 

device LEDs turn off. This adapter has generated a unique encryption key. 

 

5.  Press and hold the security button on the

 first adapter 

again for 2 seconds, then release it. The 

Power

 LED 

on the

 first adapter

 starts to flash 

after

 you release the security button

 

 

6.  Now, press and hold the security button on the

 second adapter

 for 2 seconds then release it.  The 

Power

 

LED will flash 

after

 you release the security button. 

 

NOTE: From the moment the security button is released on the first adapter in 

step 4

, you have only 

two minutes to press and release the security button on the second adapter and each other adapter 
you would like to add to the network. Each adapter’s security button must be pressed and released 
within the two minutes allowed for the adapters to share the same encryption key, and be able to 
communicate. 

 

7.  Both the

 first adapter

 and the

 second adapter

 are now on a secure, encrypted network. 

 
LED Indicators 

 

The different colors of the 

link

 LED indicate different power line throughput conditions. 

Red

 means the condition is poor and less than 50Mpbs, 

Orange

 indicates a fair line condition of 50-100Mbps, 

Green

 means the line is in good condition with over 100Mbps throughput. 

You can still maintain a network with different line conditions, but performance will vary.

 

 
Resetting an HPE 200AVP Ethernet adapter

 

 

The HPE 200AVP Ethernet adapter 

must

 be plugged in to restore it to factory defaults. Using a small object like a 

paper clip, depress and hold the reset button until the LEDs begin to flash. The reset button will need to be 
depressed for about 10 to 15 seconds for the reset to occur. 

 

The Reset button can be accessed via the small hole on the adapter, next to the Security button.

 