Communication profiles
46
behaviour is that the reference speed of the drive is set to the
requested value.
This is an example of
Explicit Messaging
where each attribute of a
class is set individually. While this is allowed, it is inefficient.
Instead
Implicit Messaging
using Input and Output Assembly
Instances is recommended.
Implicit Messaging
allows the
Ethernet/IP Master to set or get predefined groups of attributes in
a single message exchange. Assembly Instances supported by
the RETA-01 are listed and defined in chapter
,
page
ODVA output attributes
This section briefly describes the instances found in the ODVA
AC/DC Drive Profiles output assemblies. Not all attributes listed
here will be supported by all output assembly instances.
Run Forward & Run Reverse (Control Supervisor Object)
These attributes are used to assert run and stop commands to
Control Supervisor Object state machine according to the
following table.
Table 9. Run/Stop event matrix
Fault Reset (Control Supervisor Object)
This attribute resets a drive fault on a transition from zero to one if
the condition that caused the fault has been cleared.
RunFwd
RunRev
Trigger event
Run type
0
0
Stop
N/A
0
!
1
0
Run
RunFwd
0
0
!
1
Run
RunRev
0
!
1
0
!
1
No action
N/A
1
1
No action
N/A
0
!
1
1
Run
RunRev
1
0
!
1
Run
RunFwd
Summary of Contents for RETA-01
Page 1: ...ABB Drives User s Manual Ethernet Adapter Module RETA 01 ...
Page 2: ......
Page 4: ......
Page 6: ...Safety instructions 6 ...
Page 10: ...Table of Contents 10 ...
Page 14: ...Introduction 14 ...
Page 28: ...Quick start up guide 28 ...
Page 30: ...Mechanical installation 30 ...
Page 32: ...Electrical installation 32 ...
Page 40: ...Drive configuration 40 ...
Page 80: ...Communication 80 ...
Page 82: ...Fault tracing 82 ...
Page 85: ......