Mechanical installation 45
Installation procedure
WARNING!
Make sure that dust or other contaminants do not go into the
inverter during the installation.
WARNING!
Make sure that the mounting surface can hold the weight of the
unit.
To install the wall-mounting plate:
1. Use the pilot securing point (a) to mark the position of the wall-mounting plate in
the intended place.
2. If it is necessary, make a hole in the surface and install an appropriate plug.
3. Install the pilot screw, but do not tighten it.
4. Let the wall-mounting plate hang from the pilot screw or use a spirit level to make
sure that it is level.
5. Mark the remaining 4 securing points (b).
6. If it is necessary, make holes on to the mounting surface and install the
appropriate plugs.
7. Use the appropriate screws to fasten the wall-mounting plate to the mounting
surface.
8. Tighten the pilot securing screw.
W2
W2
W3
W3
H2
a
b
b
b
b