82 Start-up
Received packets
0…4294967295
Count of the received valid packets
addressed to the inverter. In normal
operation, the number increases
constantly.
To reset the count, push the
Reset
button on the control unit for 3
seconds.
Transmitted packets
0…4294967295
Count of the transmitted valid
packets addressed to the inverter. In
normal operation, the number
increases constantly.
To reset the count, push the
Reset
button on the control unit for 3
seconds.
All packets
0…4294967295
Count of the valid packets
addressed to any device on the bus.
In normal operation, the number
increases constantly.
To reset the count, push the
Reset
button on the control unit for 3
seconds.
UART errors
0…4294967295
Count of the character errors
received by the inverter. An
increasing count indicates a
configuration problem.
To reset the count, push the
Reset
button on the control unit for 3
seconds.
CRC errors
0…4294967295
Count of the packets with a CRC
error received by the inverter. An
increasing count indicates
interference on the bus.
To reset the count, push the
Reset
button on the control unit for 3
seconds.
To set up the remote monitoring interface:
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Product manual PRO 33 0 TL string inverters ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 32: ...32 Hardware description ...
Page 40: ...40 Installation requirements ...
Page 70: ...70 Electrical installation ...
Page 74: ...74 Installation checklist ...
Page 110: ...110 Maintenance ...
Page 134: ...134 Navigation map The navigation map ...
Page 136: ...Contact us www abb com solarinverters 3AUA0000123261 Rev B EN 2015 06 18 ...