Operation of the L240
26
6.2 Operation without PIN
code (access level 0)
In access level 0, the user can operate the panel without entering the PIN
beforehand. All functions can be inhibited by the user without previous entry
of the PIN (e.g. public access).
In the unset state, the time, the date and the system state are displayed:
20:01 28 Nov 08
Int Unset
In the default delivery state, the buttons
1
,
2
,
3
,
4
and
5
can be operated
directly and the functions can be executed. By pressing button
X
, you return
to the normal display from the selected function.
6.2.1 Button 1 “Int Set”
Button
1
switches the area internal set; re-pressing will switch the area back
to unset. The internal set state is indicated on the display and the unset LED
is off. In the internally set state, the internally set switched off detector
circuits are not evaluated and do not trigger an internal alarm (e.g. motion
detectors).
An external setting attempt performed externally when the system is
internally set causes an unset (for people returning home late). Only the
area, which is assigned to the keypad, can be internally set.
20:01 28 Nov 08
Int Set
6.2.2 Button 2 “Cct Off”
Button
2
switches a detector circuit off or on. First of all the shut down (only
for internally set or also for externally set) must be enabled in the
programming of the circuit by the Engineer. Thereafter, the user has the
opportunity to switch the circuit off and back on again. A circuit that is
switched off does not trigger an alarm. In the default delivery state, circuits 1
to 3 are switched off with internal setting. All the circuits, which are located in
the same area as the keypad, can be switched off.
Circuit Off
Number _ _
Entry of the number of the circuit to be switched on or off.
Cct 2
Off
On the display the current state of the circuits is displayed, e.g. circuit 02 is
switched off and does not trigger an alarm. If a text is assigned for the circuit,
it will be displayed.
By pressing button
1
the detector circuit is switched back on (detector circuit
02 – On) or with button
0
the detector circuit can be switched off (Circuit 02
– Off).
A non-enabled circuit can not be switched off by the user.
Not Available:
Not Programmed