Serial Interface L208/V.24
104
Connection
Baud-9600
Press button
1
for baud rate of 9600 Baud
In submenu “02=Operations” the “Auto” parameter should be selected.
Operations
Enable-Auto
Press button
2
to set enable to “Auto”
In submenu “03=Auth Code” an enable code can be entered. As enable
occurs without code, this function is not relevant and no entries must be
made.
Auth Code
Auth Code-000
In submenu “04=SiteID”
a 4-digit customer number must be entered for
the panel. This customer number in the panel must be identical with the
customer number in the database of the PC Software (WIN-PC). When
communication is established, both customer numbers are compared and
communication will only be possible if they are identical.
SiteID
1234
Entry of the customer number
15 LAN Interface L240/IP
15.1 General
The connection of the L240 to the PC is implemented either via a serial
interface with the Interface Module L208/V.24 or via a LAN network with the
IP Interface L240/IP.
The IP Interface is installed in the same enclosure as module L208/V24.
Two connections are also available here:
On the circuit board, the 4-core XIB-Bus from the Intrusion Alarm Panel
should be connected to the cond/-/A/B.
A network socket can be found on the right side.
On the additional connection “Keypad 0”, a L240/PT with address 0 can be
connected and can be used to program the Intrusion Alarm Panel or to
enable the connected interface module in the Hardware menu of the panel.
Note:
Only one Interface Module L208/V.24 or L240/IP can be operated on
the panel at one time.