SafeKey
66
9.2 Operating menu
9.2.1 Menu 06 – Add
Buttons
06
for accessing the “Learn” menu
Add Key/Code
Insert …
or
Push in the chip key and remove it or enter the 6-digit keypad code.
New Key/Code
Key/Code 001
The learned-in keypad code or chip key of the inserted code/key number is
displayed for three seconds (here 001). This 3-digit code/key number should
be noted together with the 7-digit key number printed on the label or the
keypad code (e.g. in the table provided in the manual “Evaluation Module
L240/BS“). After entering the 3-digit code/key number, the chip key or key
code can be modified or deleted.
Add Key/Code
Insert …
Now further keypad codes and chip keys can be learned-in or you can exit
the “Learning” level by pressing button
X
.
Keys-PIN (6-digit)
01 = Edit
02 = Show
03 = Identify
04 = Delete
05 = Text
06 = Add
07 = Access Log
08 = Copy L240/BS
09 = Change PIN
Key/Code
Number _ _ _
0 = Off
1 = Access
2 = Set/Unset
3 = Set
4 = Unset
1 = One Key/Code
2 = L240/BS
Present Key/Code
Key/Code
Number _ _ _
Key/Code
Number _ _ _
Add Key/Code
Insert …
L240/BS
Number _
L240/BS
Xx-yy
1 = Display
2 = Print
Old PIN
Input PIN:
01
11:30 08 Okt 2008
Int
Unset
Without code
1 = Int Set
2 = Cct Off
3 = Disp Cct Off
4 = Input PIN
5 = Disp CctFault
4
10 = Cancel Print
02
03
04
05
06
07
08
09
Operation without code
see chapter 0
Operating menu Management code