Configuration and Programming by the Engineer
62
Example:
Change the text for circuit 1.
Select submenu “1=Cct 1”.
Circuit
Number _ _
Enter the circuit number
Circuit 1
Cct 1
(text used up to now is displayed)
The first character flashes. Using the arrow keys you can advance in the text
line and jump to the next text position with the Enter button.
8.1.10 Menu 10 “L240/B/BS”
Menu item “10=L240/B/BS”:
The Evaluation Module L240/BS is assigned
to area 1 after it has registered. In this menu, the other areas can be
assigned. Refer to chapter 12 “SafeKey Evaluation Module L240/BS.
8.1.11 Menu 11 “XS/S1.1 KNX”
Menu item “11=XS/S1.1 KNX”:
The state of all 80 circuits of the panel as
well as other panel states such as the setting states, the alerting and the
signal devices can be monitored on the KNX system.
Each of the 80 circuits can also be contacted via the KNX. At the same time,
the setting can be undertaken via the KNX bus, and the alarm systems can
be reset via the KNX.
Every function, which allows access to the intrusion alarm system, can be
inhibited individually.
Communication to the KNX:
XS/S1.1 KNX
Standard
(
1=Standard
; 2=Output Only)
1=Standard
VdS
: Bidirectional communication.
2=Outputs Only, the panel is inhibited in the KNX system.
Enables (only with standard communication):
Inhibit or enable external setting:
XS/S1.1 KNX
Ext Set-Off
(
0=Off
;1=On)
Engineer-PIN
01 = System Size
02 = Area Opts
03 = Circuits
04 = Relay
05 = Alarm Times
06 = Keypads
07 = Concs *
08 = User Auth
09 = Text
10 = L240/B/BS*
11 = XS/1.1 KNX *
13 = 2-Conc Tamper *
15 = Defaults
16 = XIB-Detectors
8 = Edit
Engineer-PIN
01 = System Size
02 = Area Opts
03 = Circuits
04 = Relay
05 = Alarm Times
06 = Keypads
07 = Concs *
08 = User Auth
09 = Text
10 = L240/B/BS*
11 = XS/1.1 KNX *
13 = 2-Conc Tamper *
15 = Defaults
16 = XIB-Detectors
8 = Edit