Removing the balancing device
Use these procedures to remove the balancing device.
Robot position when replacing the balancing device
Note
Action
xx1500002310
Jog the robot to calibration position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
2
Unloading the pressure of the balancing device
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Mobile platform ladder
xx1500001985
Use a mobile platform ladder (or similar)
to reach the upper end of the balancing
device.
DANGER
Do not use the robot as ladder!
2
Continues on next page
450
Product manual - IRB 8700
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.