Removing the upper arm
Use these procedures to remove the upper arm.
Preparations before removing the upper arm
Note
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
1
Remove any tool or other equipment fitted
to the robot.
2
Preparations before unloading the pressure of balancing device
Note
Action
xx1500002310
Jog the robot to calibration position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
2
Unloading the pressure of the balancing devices
Use this procedure to unload both balancing devices.
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Continues on next page
Product manual - IRB 8700
245
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the upper arm
Continued