Note
Action
xx1500003100
Refit the wrist cover and tighten all screws
alternately. Repeat once.
Note
The position of axis-4 depends on the on-
going procedure.
14
xx1500002330
Screws M8x25 12.9 (17 pcs)
Tightening torque: 24 Nm
Concluding procedure
Note
Action
Axis Calibration is described in
with Axis Calibration method on page 701
Re-calibrate the robot.
1
General calibration information is included
in section
.
DANGER
Make sure all safety requirements are met
when performing the first test run.
2
Product manual - IRB 8700
309
3HAC052853-001 Revision: M
© Copyright 2015-2020 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the wrist
Continued
Summary of Contents for IRB 8700