![ABB IRB 460 Series Product Manual Download Page 288](http://html.mh-extra.com/html/abb/irb-460-series/irb-460-series_product-manual_5051288.webp)
Note
Action
xx1000001166
Remove the
cable gland cover
at the cable exit
of the motor.
Note
Make sure the gasket is undamaged! Replace
if damaged.
4
Disconnect all connectors beneath the motor
cover.
5
Connect to connector R2.MP1
•
+ : pin 2
•
-: pin 5
In order to release the brake, connect the 24
VDC power supply.
6
xx1000001167
Remove the
attachment screws
of the motor.
Use the bits extension.
7
Continues on next page
288
Product manual - IRB 460
3HAC039842-001 Revision: P
© Copyright 2012-2018 ABB. All rights reserved.
4 Repair
4.5.1 Replacing motor, axis 1
Continued
Summary of Contents for IRB 460 Series