Note
Action
Loctite 243
xx1100000197
Apply
locking liquid
on the
lock nut
.
11
Note
The recommended order of tightening the
lock nut is important to follow to avoid
future problems with the shaft.
Secure the lock nut in these three steps:
1
Tighten with a torque of
300
Nm, while
rotating the link at the same time.
2
Unscrew the lock nut
3
Tighten the lock nut finally with a
tightening torque of
90
Nm.
12
xx1100000204
Valid for design with POM sealing.
Use a screwdriver carefully to fit the POM
sealing into its final position.
13
Continues on next page
Product manual - IRB 460
253
3HAC039842-001 Revision: P
© Copyright 2012-2018 ABB. All rights reserved.
4 Repair
4.4.6 Replacing the linkage - link
Continued