Note
Action
xx1100000155
Refit the
rear cover plate
to the robot base with
its attachment screws.
5
See sections:
•
Replacing motor, axis 1 on
page 285
•
Replacing motors, axes 2 and
3 on page 294
Reconnect all connectors at
motors axes 1, 2
and
3
and refit the motor covers.
6
Reconnect connectors R2.SMB, R1.SMB1-3,
R1.SMB6 of the SMB unit.
7
Reconnect X8, X9 and X10 to the brake release
unit.
Reconnect R1.G.
Secure the
SMB cover
with its attachment
screws.
8
If cabling is used for 7th axis (option), refit the
connector R2.FB7 to the SMB cover and tighten
with 6 Nm.
WARNING
Before continuing any service work, please
observe the safety information in section
brake release buttons may be jammed after
service work on page 146
.
9
Push the cable harness up through the lower
arm.
10
Fasten the metal clamp that hold the cable
harness in the lower arm with the nuts.
11
Continues on next page
Product manual - IRB 460
155
3HAC039842-001 Revision: P
© Copyright 2012-2018 ABB. All rights reserved.
4 Repair
4.3.1 Replacing cable harness, lower end (axes 1-3)
Continued
Summary of Contents for IRB 460 Series
Page 1: ...ROBOTICS Product manual IRB 460 ...
Page 8: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 138: ...This page is intentionally left blank ...
Page 346: ...This page is intentionally left blank ...
Page 370: ...This page is intentionally left blank ...
Page 374: ...This page is intentionally left blank ...
Page 390: ...This page is intentionally left blank ...
Page 396: ......
Page 397: ......