Note
Action
xx1000001330
Pull out the cables and connectors of the SMB
unit through the frame and refit the
cable gland
with its
attachment screws
from inside the SMB
recess.
Perform this refitting with care, in order not to
damage any of the components inside the SMB
recess.
2
Tightening torque for R1.SMB: 10 Nm.
Reconnect connectors
R1.MP
and
R1.SMB
at
the robot base.
3
Attachment points are shown in the
figure
lower end (axes 1-3) on page 148
.
xx1100000156
Reconnect the
earth cable
.
4
Continues on next page
154
Product manual - IRB 460
3HAC039842-001 Revision: P
© Copyright 2012-2018 ABB. All rights reserved.
4 Repair
4.3.1 Replacing cable harness, lower end (axes 1-3)
Continued