Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
5
See section
•
Changing oil, gearbox axes 2
and 3 on page 126
.
Drain the oil from
gearbox
.
6
xx1000001182
Remove the
motor cover
.
7
xx1000001183
Remove the
cable gland cover
at the cable exit
.
Note
Make sure the gasket is not damaged! Replace
if damaged.
8
Disconnect all connectors beneath the motor
cover.
9
Continues on next page
Product manual - IRB 460
297
3HAC039842-001 Revision: P
© Copyright 2012-2018 ABB. All rights reserved.
4 Repair
4.5.2 Replacing motors, axes 2 and 3
Continued