Technical data 133
Vibration
IEC 60068-2-6:2007,
EN 60068-2-6:2008
Environmental testing Part 2:
Tests –Test Fc: Vibration
(sinusoidal)
Max. 0.1 mm (0.004 in.)
(10 to 57 Hz),
max. 10 m/s
2
(33 ft/s
2
)
(57 to 150 Hz) sinusoidal
Max. 1 mm (0.04 in.)
(5 to 13.2 Hz),
max. 7 m/s
2
(23 ft/s
2
)
(13.2 to 100 Hz)
sinusoidal
Max. 3.5 mm (0.14 in.)
(2 to 9 Hz),
max. 15 m/s
2
(49 ft/s
2
)
(9 to 200 Hz) sinusoidal
Shock
IEC 60068-2-27:2008,
EN 60068-2-27:2009
Environmental testing - Part 2-
27: Tests - Test Ea and
guidance: Shock
Not allowed
With packing max.
100 m/s
2
(330 ft./s
2
),
11 ms
With packing max.
100 m/s
2
(330 ft./s
2
),
11 ms
Free fall
Not allowed
100 mm (4 in.) for weight
over 100 kg (220 lb)
100 mm (4 in.) for weight
over 100 kg (220 lb)
Materials
Drive enclosure
• PC/ABS 2.5 mm (0.098 in.), color NCS 1502-Y (RAL 9002 / PMS 420 C)
• hot-dip zinc coated steel sheet 1.5 to 2.5 mm (0.059 to 0.098 in.), thickness
of coating 100 micrometers, color NCS 1502-Y
Package
Plywood and cardboard, bands PP.
Disposal
The main parts of the drive can be recycled to preserve natural resources and
energy. Product parts and materials should be dismantled and separated.
Generally all metals, such as steel, aluminum, copper and its alloys, and
precious metals can be recycled as material. Plastics, rubber, cardboard and
other packaging material can be used in energy recovery. Printed circuit
boards and DC capacitors (C1-1 to C1-x) need selective treatment according
to IEC 62635 guidelines. To aid recycling, plastic parts are marked with an
appropriate identification code.
Contact your local ABB distributor for further information on environmental
aspects and recycling instructions for professional recyclers. End of life
treatment must follow international and local regulations.
Applicable standards
The drive complies with the following standards.
EN 61800-5-1:2007
Adjustable speed electrical power drive systems. Part 5-1: Safety
requirements – electrical, thermal and energy
EN 60204-1:2006 + A1:2010
Safety of machinery. Electrical equipment of machines. Part 1: General
requirements
. Provisions for compliance: The final assembler of the machine
is responsible for installing
- emergency-stop device
- supply disconnecting device
- IP00 drive module into a cabinet.
IEC/EN 60529:1991 +
A2:2013
Degrees of protection provided by enclosures (IP code)
3AXD50000040437_assy
Summary of Contents for ACS880-04F
Page 1: ...ABB industrial drives Hardware manual ACS880 04F drive modules ...
Page 4: ......
Page 24: ...24 Introduction to the manual ...
Page 46: ...46 Guidelines for planning the mechanical installation ...
Page 102: ...102 Installation checklist ...
Page 106: ...106 Fault tracing ...
Page 135: ...Technical data 135 Declaration of Conformity ...
Page 136: ...136 Technical data ...
Page 140: ...140 Technical data ...
Page 142: ...142 Dimension drawings Standard configuration IP20 UL Open Type ...
Page 143: ...Dimension drawings 143 Drive module with options E208 and H370 IP20 UL Open Type ...
Page 144: ...144 Dimension drawings Drive module with options 0B051 E208 0H371 IP00 UL Open Type ...
Page 145: ...Dimension drawings 145 Drive module with options 0B051 E208 0H371 C217 IP00 UL Open Type ...
Page 146: ...146 Dimension drawings Drive module with options 0B051 0H371 IP00 UL Open Type ...
Page 147: ...Dimension drawings 147 Mounting plate 3AXD50000038119 ...
Page 148: ...148 Dimension drawings 3AXD50000038119 ...
Page 149: ...Dimension drawings 149 External control unit 3axd50000011687 ...
Page 150: ...150 Dimension drawings ...
Page 164: ...164 Safe torque off function ...