Actual signals and parameters 43
DI5
Start and stop through digital input DI5.
0 = stop, 1 = start.
Direction fixes based on parameter
(REQUEST = FORWARD).
20
DI5,4
Start and stop through digital input DI5.
0 = stop, 1 = start.
Direction control through DI4.
0 = forward, 1 = reverse.
To control direction, set the parameter
= REQUEST.
21
SOLAR
Solar mode.
is set as
• Auto [0]—inverter starts only when the DC bus
voltage is greater than the value in
• Manual [1]—inverter starts at the rising edge of the
provided the DC bus voltage is greater than
37
1003
DIRECTION
Controls or fixes the rotational direction of the motor.
REQUEST
FORWARD
Fixed to forward
1
REVERSE
Fixed to reverse
2
REQUEST
Allows rotational direction control
3
11 REFERENCE
SELECT
Defines panel reference types, external control
location selection and external reference sources and
limits.
1102
EXT1/EXT2
SEL
Defines the source from which the drive reads the
signal that selects between the two external control
locations, EXT1 or EXT2.
Note
: Only EXT1 is applicable for solar pump inverter.
EXT1
EXT1
EXT1 active. The control signal sources are defined by
parameters
0
DI1
Digital input DI1.
0 = EXT1, 1 = EXT2.
1
DI2
See selection DI1.
2
DI3
See selection DI1.
3
DI4
See selection DI1.
4
All parameters
No.
Name/
Value
Description
Def/ FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives Supplement ACS355 Solar pump inverter N827...
Page 4: ......
Page 10: ...10 Safety...
Page 14: ...14 Introduction...
Page 18: ...18 Operating principle and hardware description...
Page 30: ...30 Start up and controls...
Page 36: ...36 Program features...
Page 66: ...66 Actual signals and parameters...
Page 70: ...70 Fault tracing...
Page 76: ...76 Technical data...