34 Program features
Settings
Diagnostics
PID control macro
The ACS355 solar pump drive is designed to work with MPPT algorithm. Hence the PID
control macro is disabled and similarly when the PID control macro is enabled, the MPPT
algorithm is disabled.
See section
PID control macro
in
ACS355 user’s manual (3AUA0000066143[English]).
Pump cleaning
The solar pump inverter provides the pump cleaning function to prevent solids from
building up on pump impellers or piping. The function consists of a programmable
sequence of forward and reverse runs of the pump to shake off any residue on the impeller
or piping.
Parameter
Additional information
...
Input power of pump at points 1...5 on the PQ
performance curve.
Flow rate at points 1...5 on the PQ curve
respectively.
Efficiency of the pump.
Actual signal
Additional information
Calculated flow rate in cubic meter per hour.
Measured flow for the current day in cubic
meter.
Measured flow for current year in cubic deca
meter.
Fo
rw
a
rd
Reverse
Pump clean
time
Del
a
y t
im
e
P
22.
05
P
22.
06
Pump clean speed
Pump clean speed
Time