46 Actual signals and parameters
DI3U,4D
Digital input DI3: Reference increase.
Digital input DI4: Reference decrease.
The program stores the active speed reference (not
reset by a stop command). When the drive is
restarted, the motor ramps up at the selected
acceleration rate to the stored reference.
Parameter 2205 ACCELER TIME 2 defines the rate of
reference change.
6
COMM
Fieldbus reference REF1.
8
COMM+AI1
Summation of fieldbus reference REF1 and analog
input AI. See section Reference selection and
correction in
ACS355 User’s manual
(3AUA0000066143[English])
.
9
COMM*+AI1
Multiplication of fieldbus reference REF1 and analog
input AI. See section Reference selection and
correction in
ACS355 User’s manual
(3AUA0000066143[English])
.
10
DI3U, 4D(R)
• Digital input DI3: Reference increase.
• Digital input DI4: Reference decrease.
Stop command resets the reference to zero.
Parameter 2205 ACCELER TIME 2 defines the rate of
the reference change.
11
DI3U, 4D(NC)
• Digital input DI3: Reference increase.
• Digital input DI4: Reference decrease.
Program stores the active speed reference (not reset
by a stop command). When you restart the inverter,
the motor ramps up at the selected acceleration rate to
the stored reference.
Parameter 2205 ACCELER TIME 2 defines the rate of
the reference change.
12
AI1+AI2
Calculated reference using the equation:
14
AI1*AI2
Calculated reference using the equation:
15
AI1-AI2
Calculated reference using the equation:
16
AI1/AI2
Calculated reference using the equation:
17
All parameters
No.
Name/
Value
Description
Def/ FbEq
REF
AI1 %
( )
AI2 %
( )
50
–
+
%
( )
=
REF
AI1 %
( )
(
AI2
%
( )
×
50%)
(
)
⁄
=
REF
AI1
%
( )
50 %
( )
AI2
–
+
%
( )
=
REF
AI1
%
( )
(50 %
( )
×
AI2(%)
(
)
⁄
=
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives Supplement ACS355 Solar pump inverter N827...
Page 4: ......
Page 10: ...10 Safety...
Page 14: ...14 Introduction...
Page 18: ...18 Operating principle and hardware description...
Page 30: ...30 Start up and controls...
Page 36: ...36 Program features...
Page 66: ...66 Actual signals and parameters...
Page 70: ...70 Fault tracing...
Page 76: ...76 Technical data...