Case studies
System Manual
│155
1
2
3
Fig. 140: Physical addressing: One-family house with one panel
The counting sequence of the physical addresses can be freely selected. However, it should be
noted that no physical address can be assigned twice to a device type. This would cause
conflict.
Physical Address
Settings
Building No.
Floor No.
Units No.
Device ID
Mode
1
001
―
―
01
―
2
001
01
01
01
Master
3
―
―
―
―
One-family house
/ Terraced house
Table 8: Physical addressing: One-family house with one panel