6 Technical features
| MYLOS
®
Building Automation
MYLOS
®
Building Automation
Technical features
CE marking
- Acc. to EMC and Low-Voltage Directives
Application program
Quantity
Communication objects
Max. quantity
Group addresses
Max. quantity
Allocations
Programmable Thermostat Mylos/1.0
117
250
250
Note:
ETS 2 software and the application program are required for
programming.
After import, the application program is in ETS at ABB Sace/Heating,
Air-conditioning, Ventilation/Thermostat.
Note:
The device does not support the KNX closing function in the ETS.
If access to all devices of the project is blocked by a BCU key (ETS
3), it will not have any effect on this device. It can still be read and
programmed.
Supplied state
The device is supplied with the physical address 1.0.1. The application program is preloaded. It is therefore only
necessary to load group addresses and parameters during commissioning. However, the complete application program
can be reloaded if required. A longer downtime may result if the application program is changed or after a discharge.
Assignment of the physical address
The assignment and programming of the physical address is carried out in the ETS. The device features a Programming
button for assignment of the physical device address. The red Programming LED lights up, after the button has
been pushed. It switches off, as soon as the ETS has assigned the physical address or the Programming button is
pressed again.
Cleaning
If devices become dirty, they can be cleaned using a dry cloth or a cloth dampened with a soapy solution. Corrosive
agents or solutions should never be used.
Download behaviour
Depending on the PC, which is used, the progress bar for the download may take up to one and a half minutes,
before it appears, due to the complexity of the device.
Maintenance
The device is maintenance-free. No repairs should be carried out by unauthorised personnel if damage occurs, e.
g. during transport and/or storage.