Troubleshooting
9-10
41-001160-03, Rev 00, Releaes 2.4
IP Phone Administrator Guide
4
Click
to save your settings.
5
Click on
Operation->Reset
.
6
In the "
Restart Phone
" field click
to restart the IP phone.
To set blog modules:
7
Select a module for which you want to have log files created, and sent to a blog.
8
Enter a debug level value in the “
Debug Level
” field for a module. Valid values are:
The value of “
0
” turns all debug levels OFF for a module. The value of “
65535
” turns all debug levels
ON for a module.
To turn two or more debug levels on at the same time, you add the value associated with each level.
For example, Fatal Warnings = 1 + 2 + 4 =
7
log module linemgr:
7
log module user interface:
7
log module sip:
7
In the above example, fatal errors, general errors, and warnings are logged for the line manager, user
interface, and SIP call control modules.
9
Click
to save your settings.
Aastra Web UI
Step
Action
Debug Level
Value
Fatal Errors
1 (default)
Errors
2
Warnings
4
Init
8
Functions
16
Info
32
All debug
levels OFF
0
All Debug
Levels ON
65535
Draft 1
Summary of Contents for 675i Series
Page 4: ...D r a f t 1 ...
Page 26: ...Non Blocking HTTP Connections F 90 XML SIP Notify F 91 Limited Warranty D r a f t 1 ...
Page 30: ...D r a f t 1 ...
Page 70: ...D r a f t 1 ...
Page 90: ...D r a f t 1 ...
Page 745: ...D r a f t 1 ...
Page 1026: ...D r a f t 1 ...
Page 1068: ...D r a f t 1 ...
Page 1072: ...D r a f t 1 ...
Page 1076: ...D r a f t 1 ...
Page 1182: ...Index 12 41 001160 00 Release 2 2 Rev 05 Index D r a f t 1 ...
Page 1183: ...D r a f t 1 ...