Global SIP Settings
4-82
41-001160-03, Rev 00, Releaes 2.4
IP Phone Administrator Guide
9
In the "
Line Mode
" field, select "Generic" for normal mode, "BroadSoft SCA" for a BroadWorks
network, or "Nortel" for a Nortel network.
To configure SIP network settings:
10
In the "
Proxy Server
" field, enter an IP address or fully qualified host name of the SIP proxy server.
11
In the "
Proxy Port
" field, enter a port number for accessing the SIP proxy server.
12
In the "
Backup
Proxy Server
" field, enter an IP address or fully qualified host name for the backup
proxy server.
13
In the "
Backup
Proxy Port
" field, enter a port number for accessing the backup proxy server.
14
In the "
Outbound Proxy Server
" field, enter the SIP outbound proxy server IP address or fully
qualified domain name. This parameter allows all SIP messages originating from a line on the IP
phone, to be sent to an outbound proxy server.
Note:
If you configure an outbound proxy and registrar for a specific line, and you also configure a
global outbound proxy and registrar, the IP phone uses the global configuration for all lines except
line 1. Line 1 uses the outbound proxy and registrar that you configured for that line.
15
In the "
Outbound Proxy Port
" field, enter the port on the IP phone that allows SIP messages to be
sent to the outbound proxy server.
16
In the "
Registrar Server
" field, enter an IP address or fully qualified host name for the SIP registrar
server. A global value of 0.0.0.0 disables registration. However, the phone is still active and you can
dial using username@ip address of the phone.
If the Registrar IP address is set to 0.0.0.0 for a per-line basis (i.e, line 1, line 2, etc.), then the
register request is not sent, the "No Service" message does not display, and the message waiting
indicator (MWI) does not come on.
17
In the "
Registrar Port
" field, enter the port number associated with the Registrar.
18
In the "
Backup
Registrar Server
" field, enter an IP address or fully qualified host name for the
backup registrar server. A global value of 0.0.0.0 disables registration. However, the phone is still
active and you can dial using username@ip address of the phone.
If the Backup Registrar IP address is set to 0.0.0.0 for a per-line basis (i.e, line 1, line 2, etc.), then
the register request is not sent, the "No Service" message does not display, and the message waiting
indicator (MWI) does not come on.
19
In the "
Backup
Registrar Port
" field, enter the port number associated with the backup registrar.
20
In the "
Registration Period
" field, enter the requested registration period, in seconds, from the
registrar.
Aastra Web UI
Step
Action
Draft 1
Summary of Contents for 675i Series
Page 4: ...D r a f t 1 ...
Page 26: ...Non Blocking HTTP Connections F 90 XML SIP Notify F 91 Limited Warranty D r a f t 1 ...
Page 30: ...D r a f t 1 ...
Page 70: ...D r a f t 1 ...
Page 90: ...D r a f t 1 ...
Page 745: ...D r a f t 1 ...
Page 1026: ...D r a f t 1 ...
Page 1068: ...D r a f t 1 ...
Page 1072: ...D r a f t 1 ...
Page 1076: ...D r a f t 1 ...
Page 1182: ...Index 12 41 001160 00 Release 2 2 Rev 05 Index D r a f t 1 ...
Page 1183: ...D r a f t 1 ...