Operation and Maintenance
223
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Mains voltage failure
Event message once mains power is restored
• Mains power has failed more frequently than
entered in the trigger table
Date, time
Malfunction
A hardware or software error has occurred. The
error ID can help Support to pinpoint the possi-
ble cause of the error.
Error ID, date, time
Monitor event
Monitor event
Monitor Type, Date, Time
No DECT DSP channels avail-
able
DECT channels on DSP-0x overloaded
Date, time
No DTMF receiver for inte-
grated mobile phones
availa-
ble
A permanent DTMF receiver (for detection suf-
fix dialling function codes) could not be
assigned to an integrated mobile phone with
enhanced functionality.
BCS Ref., date, time
No response from network
No answer to Call Setup on BRI-T/PRI interface
Port number of the exchange
line circuit, date, time
No response from user
No answer to incoming DDI call from user on S
bus or DSI
DDI No., date, time
Node: Connection lost
A node is not connected to the Master for a cer-
tain amount of time (configurable).
Node number, date, time
Node: Connection re-estab-
lished
A node is reconnected with the Master for a cer-
tain amount of time (configurable) after an
interruption.
Node number, date, time
NTP: Synchronisation failed
Time synchronization via the NTP server (NTP =
Network Time Protocol) has failed.
Date, time
NTP: Synchronisation re-
established
Time synchronization via the NTP server (NTP =
Network Time Protocol) has been restored.
Date, time
Outgoing call rejected
Call rejected by the network
• On any line: error code 34
• On required line group:
error code 44
Port number of the exchange
line circuit, cause, date, time
Overheat
The temperature inside the communication
server is too high. The appropriate measures
must be taken immediately to improve the heat
dissipation, e.g. by providing the required
clearances, lowering the ambient temperature
or installing the fan from the rack-mounting set
(Aastra 430 only).
Card number, temperature,
date, time
Port out of service
A port previously in operation has stopped
functioning.
Number of the slot, relevant
port number, date, time
QSIG licence limit reached
Maximum number of licensed outgoing con-
nections with QSIG protocol exceeded
Route number, user number,
date, time
Radio unit port active
The radio unit is responding again
Card number, port number,
date, time
Register error
• Card not fitted
• Card not logged on
• Card defective
Card number, date, time
Event / error message
Trigger condition
Details