Installation
118
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Power available B:
Applies to the SB-4+/SB-8 DECT radio units with hardware version "-2" if they are
connected to a basic system with hardware version "-2" or to an EADP4 interface
card with hardware version "-3".
Fig. 44
Power available B on the DSI-AD2 bus
Notes
– If another system phone is operated on the DSI-AD2 bus in addition to
an Aastra 5361, Aastra 5370 or Aastra 5380, at least one phone must be
powered by a local power supply unit.
– An Aastra 5370 or Aastra 5380 with an Aastra M535 expansion key
module always requires a power supply unit.
– An Aastra 5380 with 3 Aastra M530 expansion key modules always
requires a power supply unit. With 2 expansion key modules the use of
power supply unit depends on the line length and the line cross-sec-
tion.
d = 0.6 mm
d = 0.5 mm
d = 0.4 mm
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
2600
2700
2800
2900
3000
3100
3200
3300
3400
3500
3600
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
1200
620
600
580
560
540
520
500
480
460
440
420
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
d=0.6mm
d=0.5mm
d=0.4mm
Pmax [mW]
R [Ohm]
d=0.4mm
d=0.5mm
d=0.6mm
Power available B on the DSI-AD2 bus Pmax [mW]
Loop resistance R [Ohm]
Line length L [m]
d: Wire diameter